管家婆期期准免费资料精选> Products> Laser Particle Size Analyzer> Laser Particle Size Analyzer Sync
Product Details
Laser particle size analyzer Sync
Picture of Laser Particle Size Analyzer Sync
Reference quote:
Negotiable
Brand:
Microtrac
Attention:
7655
sample:
No
model:
Sync
Origin:
USA / Germany
Information integrity:
Typical user:
No
Resolution:
0.6%
Measuring range:
0.01-4000um
measure time:
10-30 seconds
Decentralized mode:
Wet and dry dispersion
Reproducibility:
<1%
Certification Information
年 Platinum Member 9th Year
Name: DKSH (Shanghai) Co., Ltd. (DKSH Huajia)
Authentication: Business information has been verified Visits: 1757203
Mobile site
Scan for easier mobile access
Product Categories
Product introduction

In 2018, the United States Microtrac company launched a world-leading laser particle size analyzer Sync, which integrates static laser diffraction technology and dynamic image analysis technology, which can provide users with more information about particle particles than before. Sync can use the same instrument, the same sample, one injection, the same sample cell, one measurement, and get the particle size and shape results at the same time.

Whether it's optimizing particle size distribution or looking for more specific ways to showcase material properties, this new Macchik instrument will increase customer productivity and enable them to explore and optimize their material properties.

Using our patented method, when using the laser diffraction method for wet or dry measurement, you can also take photos with a high-speed camera. The test knot data will be collected by Flex software and presented to the user with particle size and morphology information. Flex software is very powerful, and the user interface is very intuitive and very easy to use. Compared to previous instruments that only measured particle size with laser diffraction, Sync gives users more detailed information about their materials.

FlowSync: Wet Injection System
FlowSync is connected to the host with fully automatic dosing, draining, pre-circulation and circulation operations, which can ensure that the particles are not affected by external human influence and improve the repeatability of measurement results.

TurboSync: dry injection system
TurboSync: The main function is to provide the appropriate dispersed sample to the sample cell.

In addition to the particle size distribution of laser diffraction technology, some key features of dynamic image analysis technology are also integrated:
-Provide chart and table report format of granularity and granularity;
-X and Y axis can choose any parameter to display the position of each particle;
-Real-time visualization of particles in the measurement process or recall of previous image files;
-Provide more than 30 size and shape parameters;
-Can inspect and search for individual particles provided;
-Search and filter function allows you to search for the particles you want in the area of interest;
-The mixed characteristics of innovative laser diffraction technology and dynamic image analysis technology provide accurate particle size distribution and extend the upper measurement limit to 4000um;

application:
Metal powders, industrial minerals, ceramics, glass beads, batteries, oil and gas, chemicals, coatings / pigments, pharmaceuticals, coatings, cement, 3D printing, etc. . .

Features:
-One instrument has two analysis methods: laser diffraction method and dynamic image analysis method
-Simultaneous analysis of particle size and morphology
-The same instrument, the same sample, the same pipeline, the same sample cell, one run, at least more than 30 kinds of particle size and shape parameters
-Plug-in design, dry and wet conversion is very simple, no need to connect pipes
-Patented three-laser design, which can be all-red laser, all-blue laser or a mixture of red and blue lasers, provides different measurement ranges for users with different needs and gives the best accuracy
-Fixed position solid-state lasers do not require preheating
-The design of the Fourier optical path ensures that the incident angle of the laser is constant
-The whole pipeline design conforms to the hydromechanical design, there is no dead angle, as long as the added sample can be detected.
-Flex software is very easy to use
-Powerful reporting functions provide a lot of information on granular and granular data

Technical Parameters:
Measurement range: 0.01-4000um
Accuracy: ± 0.6%
Laser: 780nm red solid-state laser, 405nm blue solid-state laser Detection system: real-time detection, 151 detection units are arranged in line with each other. Detection angle: 0.02-163 °
Typical analysis time: 10-30 seconds Grain shape analysis: 5M pixels (2560 × 2048)
Camera speed: max 62 fps
Wet injection system: Inner cavity volume: 200ml
Flow rate: 0-65ml / sec
Inlet pressure: max. 50psi (345kpa)
Dry injection system: Maximum dispersion pressure: 100psi (689kpa)
Minimum flow: 5 CFM (8.5 m3 / h) at 50 psi (345 kPa)
No vacuum requirements for dry powder, water and oil pollutants: Vacuum must reach or exceed 50 cubic feet (85 cubic meters / hour)
Comply with standards: ISO13320 (laser diffraction method) and ISO13322 (dynamic image analysis method)
Power requirements: 90-264 volt AC power, 47-63 Hz, single-phase environmental requirements: temperature: 5-40 °
Humidity: up to 90%
Storage temperature: -10-50 °
Appearance size: 46H x 82W x 50D cm